I can’t find part no. AS-OH-0011 / ASOH0011
If you are looking for part no. AS-OH-0011 (or ASOH0011), that part number is for the lamp lead that connects the UV lamp to the Ultravation UV power supply.
This lamp lead connects to the Ultravation 12” UV lamps or the 17” UV lamps with the following part numbers:
Original lamps that ship with the UV system (1-year replacement schedule)
-
12” AS-IH-1010 https://ultravationstore.com/?s=AS-IH-1010
-
17” AS-IH-1012 https://ultravationstore.com/?s=AS-IH-1012
Or you can upgrade to the UltraMAX T3™ UV lamp with 40% more UV germicidal effectiveness and a 2-year lamp life. It replaces the original EZUV lamps. They can be found here:
- 12″ AS-IH-1001 https://ultravationstore.com/?s=asih1001
- 17″ AS-IH-1003 https://ultravationstore.com/?s=asih1003
AN IMPORTANT NOTE: A T3™ lamp is slightly larger in diameter than the earlier lamp requiring a 1” opening. This is ¼” larger than the requirement for the earlier lamp. The opening for the lamp, in most installations of the earlier model, is large enough to accommodate the upgraded lamp. However, in some instances, installing a T3 UV lamp requires enlarging the hole.
We recommend measuring the opening before placing your order. If the hole is not large enough for a T3™ lamp the options are to 1) enlarge it to take advantage of the T3’s benefits or 2) purchase the original
If you need to replace the lamp lead, please contact us.